Original: $294.00
-65%$294.00
$102.90The Story
SkyTech Gas E-STOP Timer (1 Hour) - ESTOP-1.0
The E-Stop is a manual shut-off valve/mechanical timer designed to be installed on the inlet side of a gas appliance to enable the user to control the time that gas is allowed to flow to a gas appliance. This is a mechanical timer that has the ability to control gas flow for 1-hour (60 minutes) using the E-STOP1-0 model or 2.5-hours using the E-STOP2-5 model. In addition, the E-Stop has a safety feature (red knob) that enables the user to shut the gas completely OFF immediately in case of an emergency.
The E-Stop body 4-inches tall by 2-7/8 -inches wide and can replace a manual shut-off valve and meet local code requirements as the accessible shut-off valve. It can be use for multiple applications from gas fire pits, gas grills, gas logs, gas torch lights, etc. where a shut-off valve is a requirement.
Features:
|
|
Specifications:
| Timer Accuracy: | +- 15% |
| Fuel Type: | Natural Gas or Propane (No Conversion Required) |
| CSA Rated Capacity: | 165,000 BTU/hr at 1" Pressure Drop (Natural Gas) |
| Maximum Pressure: | 1/2" PSI |
| Connection: | 1/2" NPT inlets / outlets - Side or Back |
| CSA Certified: | ANSI Z21.21; CSA 6.5 |
| Ambient Temperature: | 0 to 175F (79C) |
Dimensions:
| Height: | 4" |
| Width: | 2-7/8" |
| Depth: | 2-1/8" |
Documents:
| Instruction Manual | Link |

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
SkyTech Gas E-STOP Timer (1 Hour) - ESTOP-1.0
The E-Stop is a manual shut-off valve/mechanical timer designed to be installed on the inlet side of a gas appliance to enable the user to control the time that gas is allowed to flow to a gas appliance. This is a mechanical timer that has the ability to control gas flow for 1-hour (60 minutes) using the E-STOP1-0 model or 2.5-hours using the E-STOP2-5 model. In addition, the E-Stop has a safety feature (red knob) that enables the user to shut the gas completely OFF immediately in case of an emergency.
The E-Stop body 4-inches tall by 2-7/8 -inches wide and can replace a manual shut-off valve and meet local code requirements as the accessible shut-off valve. It can be use for multiple applications from gas fire pits, gas grills, gas logs, gas torch lights, etc. where a shut-off valve is a requirement.
Features:
|
|
Specifications:
| Timer Accuracy: | +- 15% |
| Fuel Type: | Natural Gas or Propane (No Conversion Required) |
| CSA Rated Capacity: | 165,000 BTU/hr at 1" Pressure Drop (Natural Gas) |
| Maximum Pressure: | 1/2" PSI |
| Connection: | 1/2" NPT inlets / outlets - Side or Back |
| CSA Certified: | ANSI Z21.21; CSA 6.5 |
| Ambient Temperature: | 0 to 175F (79C) |
Dimensions:
| Height: | 4" |
| Width: | 2-7/8" |
| Depth: | 2-1/8" |
Documents:
| Instruction Manual | Link |